Your cart is empty

3KL6130-1AB02 SW.DISCON. W.F. 630A/3P/FUSE SIZE3/2/UR

Part No.:
3KL6130-1AB02
Manufacturer:
Weight:
14kg

Product Information

SWITCH DISCONNECTOR WITH LVHRC FUSES SIZE 3/2 IU=630A, UE=690V, 3-POLE, UR
General technical details:
Product brand nameSENTRON
product designationSwitch Disconnector with Fuses 3KL
Number of poles3
Installation size of fuse-link3 and 2
Installation size of disconnecting link3 and 2
Acceptability for application
  • main switch
Yes
  • switch disconnector
Yes
  • emergency stop switch
No
  • safety cut-out switch
Yes
  • maintenance/repair switch
Yes
Product extension
  • optional / motor drive
No
  • optional / voltage trigger
No
Design of the operating mechanismmanual operating mechanism
Product equipment / interlockYes
Type from devicefixed mounting
type of voltageAC/DC
Continuous current / rated valueA630
Breaking capacity limit short-circuit current (lcu) / at 400 V / rated value
  • optional / interlock
Yes
  • auxiliary switch
Yes
Active power loss
  • maximum
W140
  • per conductor / typical
W47
Insulation voltage / rated valueV1,000
Impulse voltage resistance / rated valueV8,000
Item designation
  • according to DIN EN 61346-2
Q
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
Q
Fuse systemLV HRC fuse
Main circuit:
Design of the electrical connection
  • for main current circuit
flat connector
Number of poles / for main current circuit3
Operating current
  • at AC-21
  • at 500 V / rated value
A630
  • at 690 V / rated value
A630
  • rated value
A630
  • at AC-22a
  • at 400 V / rated value
A630
  • at 500 V / rated value
A630
  • at 690 V / rated value
A630
  • at AC-23a
  • at 400 V / rated value
A630
  • at 500 V / rated value
A630
  • at 690 V / rated value
A630
  • at AC-3 / at 400 V
  • rated value
A630
  • at DC-23a
  • at 400 V / rated value
A630
Service power
  • at AC-23a
  • at 400 V / at 50/60 Hz / rated value
W335,000
  • at 500 V / at 50/60 Hz / rated value
W335,000
  • at 690 V / at 50/60 Hz / rated value
W425,000
Operating voltage / for DC / rated valueV440
Operating voltage / at 50/60 Hz / for AC / rated valueV690
Auxiliary circuit:
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Number of change-over switches / for auxiliary contacts0
Installation/mounting/dimensions:
Built in orientationany
Design of the load switch
  • Strip form
No
Type of the driving mechanism
  • motor drive
No
Type of mountingsurface mounting and installation
  • Rail installation
No
  • front mounting with central fixation
No
  • front mounting with 4-hole fixation
No
Widthmm345
Heightmm270
Depthmm240
Ambient conditions:
Ambient temperature
  • during operating
°C-25…55
  • during storage
°C-50…80
Protection class IPIP00
Verification of suitabilityUR

2 Units in Stock


Call for Availability

Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange