3LD2003-0TK53 EM. STOP SWITCH 16A/690V 400V/7.5KW

Part No.:
3LD2003-0TK53
Manufacturer:
Weight:
0.5kg

Product Information

EMERG. STOP SWITCH 3-POLE IU=16, P/AC-23A AT 400V=7.5KW FRONT MOUNTING FOUR-HOLE MOUNTING ROTARY ACTUATOR RED/YELLOW (EMERG. STOP)
General technical details:
Product brand nameSENTRON
product designationmain and EMERGENCY-OFF switches
Type from devicefixed mounting
Design of the operating mechanismrotary actuator, red/yellow
Protection class IPIP65
Number of poles3
Acceptability for application
  • switch disconnector
Yes
  • main switch
Yes
  • safety cut-out switch
Yes
  • emergency stop switch
Yes
  • maintenance/repair switch
Yes
Product equipment / interlockYes
Type of the driving mechanism / motor driveNo
Product extension / optional
  • motor drive
No
  • voltage trigger
No
Ambient temperature / during operating°C-25…55
Insulation voltage / rated valueV690
Impulse voltage resistance / rated valueV6,000
Active power loss / per conductor / typicalW0.5
Mechanical operating cycles as operating time / of the main contacts / typical100,000
Item designation / according to DIN EN 61346-2S
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750S
Main circuit:
Continuous current / rated valueA16
Operating current / at AC-21 / rated valueA16
Short-time current resistance (Icw) / at 690 V / limited to 1 s / rated valueA340
Operating frequencyHz50…60
Operating voltage / at 50/60 Hz / for AC / rated valueV690
Service power / at AC-3
  • at 400 V / rated value
kW5.5
  • at 690 V / rated value
kW5.5
Service power / at AC-23a
  • at 400 V / rated value
kW7.5
  • at 690 V / rated value
kW7.5
Operating cycles / maximum1/h50
Auxiliary circuit:
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Number of change-over switches / for auxiliary contacts0
Continuous current / of the auxiliary contact / rated valueA10
Operating voltage / of the auxiliary contacts / for AC / maximumV500
Insulation voltage / of the auxiliary switch / rated valueV500
Short-circuit:
Design of the fuse link / for short-circuit protection of the main circuit / necessaryfuse gL/gG: 20 A
Design of the fuse link / for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 10 A
Installation/mounting/dimensions:
Type of mountingfront mounting
  • front mounting
Yes
  • front mounting with central fixation
No
  • front mounting with 4-hole fixation
Yes
  • series installation
Yes
  • Rail installation
No
Widthmm67
Heightmm84
Depthmm92.5
Connection type:
Design of the electrical connection / for main current circuitconnection terminals
Design of the electrical connection / for auxiliary contactconnection terminals
Type of the connectable conductor cross-section / for main contacts
  • finely stranded / with conductor end processing
4 mm²
Type of connectable conductor cross section / for auxiliary contacts
  • solid
2x (0.75 to 2.5 mm2), 1x 4 mm2
  • finely stranded / with conductor end processing
2x (0.75 to 1.5 mm2), 1x 2.5 mm2
  • stranded
2x (0.75 to 2.5 mm2), 1x 4 mm2
Verification of suitabilityCSA / UL / CCC / GL / LRS / DNV / PRS
Conductor cross section that can be connected / for main contacts / solid / minimummm²1
Conductor cross section that can be connected / for main contacts / solid / maximummm²6
Conductor cross section that can be connected / for main contacts / stranded / minimummm²1
Conductor cross section that can be connected / for main contacts / stranded / maximummm²6
Conductor cross-section that can be connected / for main contacts / stranded wire / with conductor end processing / maximummm²4
Conductor cross section that can be connected / for auxiliary contacts / solid / minimummm²0.75
Conductor cross section that can be connected / for auxiliary contacts / solid / maximummm²4
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / minimummm²0.75
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / maximummm²2.5
Conductor cross section that can be connected / for auxiliary contacts / stranded / min.mm²0.75
Conductor cross section that can be connected / for auxiliary contacts / stranded / max.mm²4