Your cart is empty

3RF2320-1BA04 SEMI-CONDUCTOR CONTACTOR 3RF2

Part No.:
3RF2320-1BA04
Manufacturer:
Weight:
0.2kg
Product Range:
Motors and Drives

Product Information

SEMI-COND. CONTACTOR 3RF2,1-PH. AC51 20A / AC15 12A 40 DEGR. C 48-460V / 24V DC INST. SWITCHING
General technical data:
Product brand nameSIRIUS
product designationsolid-state contactor
Product functioninstantaneous switching
Number of poles / for main current circuit1
Protection class IPIP20
Product designation / _1 / of the accessories that can be orderedterminal cover
Manufacturer article number / _1 / of the accessories that can be ordered
Product designation / _2 / of the accessories that can be orderedpower regulator
Manufacturer article number / _2 / of the accessories that can be ordered
Product designation / _3 / of the accessories that can be orderedconverter
Manufacturer article number / _3 / of the accessories that can be ordered
Product designation / _4 / of the accessories that can be orderedload monitoring
Manufacturer article number / _4 / of the accessories that can be ordered
Product designation / _5 / of the accessories that can be orderedload monitoring, basis
Manufacturer article number / _5 / of the accessories that can be ordered
Ambient temperature
  • during operating
°C-25…60
  • during storage
°C-55…80
Installation altitude / at a height over sea level / maximumm1,000
Resistance against vibration / according to IEC 60068-2-62g
Resistance against shock / according to IEC 60068-2-2715g / 11 ms
Item designation
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
K
  • according to DIN EN 61346-2
Q
Number of NC contacts / for auxiliary contacts0
Number of NO contacts / for auxiliary contacts0
Number of change-over switches / for auxiliary contacts0
Main circuit:
Number of NO contacts / for main contacts1
Number of NC contacts / for main contacts0
Operating current
  • at AC-1 / at 400 V / rated value
A20
  • at AC-51 / rated value
A20
Operating current / minimummA500
Operating voltage
  • at 50 Hz / at AC / rated value
V48…460
  • at 60 Hz / at AC / rated value
V48…460
Working area related to the operating voltage
  • at 50 Hz / for AC
V40…506
  • at 60 Hz / for AC
V40…506
Operating frequency
  • rated value
Hz50…60
Relative symmetrical tolerance / of the operation frequency%10
Insulation voltage / rated valueV600
Voltage slew rate / at the thyristor / for main contacts / maximum permissibleV/µs1,000
Block voltage / at the thyristor / for main contacts / maximum permissibleV1,200
Reverse current / of the thyristormA10
Derating temperature°C40
Active power loss / total / typicalW20
Resistance against the impulse current / rated valueA600
I2t-level / maximumA²·s1,800
Control circuit:
Type of voltage / of the controlled supply voltageDC
Control supply voltage / 1
  • for DC
  • initial rated value
V15
  • final rated value
V24
Control supply voltage
  • for DC / final value for signal<0>-recognition
V5
Control current
  • at minimum control supply voltage / for DC
mA2
  • for DC / rated value
mA15
Fuse assignments
Installation/mounting/dimensions:
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Type of fixing/fixation / series installationYes
Design of the thread / of the screw for fastening of the operating resourceM4
Tightening torque / of the screw for fastening of the operating resourceN·m1.5
Widthmm22.5
Heightmm100
Depthmm140.5
Connections:
Design of the electrical connection / for main current circuitscrew-type terminals
Design of the thread / of the connection screw / for main contactsM4
Tightening torque / for main contacts
  • with screw-type terminals
N·m2…2.5
Tightening torque (lbf·in) / for main contacts
  • with screw-type terminals
lbf·in18…22
Type of the connectable conductor cross-section
  • for main contacts
  • solid
2x (1.5 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
  • finely stranded
  • with conductor end processing
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²
  • for AWG conductors
  • for main contacts
2x (14 ... 10)
  • for auxiliary and control contacts
1x (AWG 20 ... 12)
  • for auxiliary and control contacts
  • solid
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • finely stranded
  • with conductor end processing
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
  • without conductor final cutting
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.0 mm²)
Conductor cross section that can be connected
  • for main contacts
  • solid
mm²1.5…6
  • stranded wire
  • with conductor end processing
mm²1…10
  • for auxiliary and control contacts
  • solid
mm²0.5…2.5
  • stranded wire
  • with conductor end processing / minimum
mm²0.5…2.5
  • without conductor final cutting
mm²0.5…2.5
AWG number / as coded connectable conductor cross-section / for main contacts10…14
Design of the electrical connection / for auxiliary and control current circuitscrew-type terminals
Design of the thread / of the connection screw / of the auxiliary and control pinsM3
AWG number / as coded connectable conductor cross-section
  • for auxiliary and control contacts
20…12
Skinning length / of the cable / for main contactsmm7
Skinning length / of the cable / for auxiliary and control contactsmm7
Tightening torque / for auxiliary and control contacts
  • with screw-type terminals
N·m0.5…0.6
Tightening torque (lbf·in) / for auxiliary and control contacts
  • with screw-type terminals
lbf·in4.5…5.3

1 Units in Stock


Call for Availability

Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question

Additional Images